Quick Answers
Who is the responsible person in an RTM-managed block?
The RTM company — as the entity that has taken on the management functions of the landlord, including management of the common parts. The responsible person has a non-delegable duty to carry out a suitable and sufficient fire risk assessment of the common parts, implement its recommendations, and keep it under review. Appointing a fire risk assessor does not transfer the legal responsibility.
How often must the fire risk assessment be reviewed?
Whenever there is reason to believe it is no longer valid, or after any significant change in the building or its occupancy. In practice, annual review as a minimum is appropriate for all residential blocks. For higher-risk buildings above 11 metres, more frequent review is expected and the Building Safety Act 2022 imposes additional ongoing monitoring obligations.
What are the fire door inspection requirements?
Annual inspection for all blocks; quarterly inspection of communal fire doors for blocks above 11 metres; quarterly inspection of all fire doors including flat entrance doors for blocks above 18 metres. Inspections must be by a competent person and must check door leaf condition, seals, self-closers, intumescent strips, and hardware. Failed doors must be repaired or replaced promptly.
The legal framework: fire safety in residential blocks is governed primarily by the Regulatory Reform (Fire Safety) Order 2005 (RRFSO), which applies to the common parts of all residential blocks and imposes obligations on the "responsible person." The Building Safety Act 2022 (BSA 2022) created additional and more intensive obligations for "higher-risk buildings" — residential blocks above 18 metres or above seven storeys. The two regimes overlap in higher-risk buildings — both apply concurrently and must both be complied with. The Fire and Rescue Authority enforces the RRFSO; the Building Safety Regulator enforces the BSA 2022 higher-risk building regime.
The criminal dimension: non-compliance with the RRFSO is a criminal offence under Article 32. The responsible person can be prosecuted, fined without limit, or imprisoned for up to two years for failing to carry out or maintain a fire risk assessment, failing to implement its recommendations, or failing to maintain fire safety measures in the common parts. These are not regulatory penalties — they are criminal sanctions. RTM directors who delegate fire safety management to their managing agent without any oversight of whether the obligations are being met are not protected from personal liability by that delegation.
Key Takeaways
The RTM company is the responsible person for the common parts
Where an RTM company has taken over management of a residential block, it becomes the responsible person under the RRFSO for the common parts of the building — the corridors, stairwells, lobbies, roof spaces, plant rooms, and any other areas under the RTM company's control. This is a legal status with criminal consequences for non-compliance. RTM directors should understand that the responsible person obligation was inherited with management — it is not something that can be delegated away or that rests with the managing agent instead of the RTM company.
A "suitable and sufficient" fire risk assessment is mandatory — not just a box to tick
The RRFSO requires the responsible person to carry out a "suitable and sufficient" fire risk assessment. This is a substantive legal standard — the assessment must genuinely identify the fire risks in the building, evaluate them, and specify the measures needed to reduce them to an acceptable level. An assessment carried out by an unqualified person, or one that simply copies a template without engaging with the specific building's characteristics, does not meet this standard. Where a fire occurs and the assessment is subsequently found to have been inadequate, the responsible person faces both prosecution and civil liability.
Fire risk assessment recommendations must be implemented — and tracked
The fire risk assessment produces an action plan of recommendations. The responsible person's obligation does not end with the assessment — it continues through the implementation of those recommendations. Where a fire risk assessment has been carried out and its recommendations are not being implemented, the responsible person has identified the risks and chosen not to address them. This is the worst possible evidential position if a fire subsequently occurs. Every recommendation in the fire risk assessment action plan must be tracked, given a responsible owner and a deadline, and confirmed as completed in writing.
The fire risk assessor must be competent — and independence matters
The RRFSO requires that where the responsible person appoints someone to assist with fire risk assessment, that person must be competent — having sufficient training, experience, and knowledge. The managing agent is not automatically competent to carry out a fire risk assessment simply by virtue of being a managing agent. For residential blocks, a qualified fire risk assessor (holding BAFE SP205 accreditation or equivalent, and registered on a recognised competency scheme) should carry out the assessment. Self-conducted assessments by managing agents who are not qualified fire risk assessors may not meet the "suitable and sufficient" standard.
Fire door failures are one of the most common RRFSO non-compliance findings
Fire doors are the primary passive fire protection measure in most residential blocks — they contain fire and smoke to the compartment of origin, buying time for evacuation. A fire door with a failed self-closer, missing intumescent strip, or door leaf damage does not fulfil its fire protection function. Fire door condition is the single most frequently cited non-compliance finding in Fire and Rescue Authority enforcement inspections of residential blocks. Where fire doors are in poor condition, the responsible person's position in any subsequent fire investigation is very difficult to defend.
Higher-risk buildings have a separate regulatory regime that runs in parallel
Residential blocks above 18 metres are higher-risk buildings under the Building Safety Act 2022. They must be registered with the Building Safety Regulator, must have a safety case report demonstrating how risks are managed, and are subject to more intensive and more frequent regulatory scrutiny. The BSA 2022 regime runs in parallel with the RRFSO — both apply concurrently and the responsible person must comply with both. The Building Safety Regulator and the Fire and Rescue Authority both have enforcement roles in higher-risk buildings, and the two agencies share information and coordinate their enforcement activity.
Who Is the Responsible Person?
The Regulatory Reform (Fire Safety) Order 2005 imposes fire safety obligations on the "responsible person" — defined as the person who has control of the premises. In a residential block, this applies to the common parts — the areas under the landlord's or RTM company's control rather than within individual leasehold flats.
The responsible person in a residential block is:
- The freeholder (or their managing agent, if managing), where the block is managed by the freeholder
- The RTM company, where the right to manage has been acquired — because the RTM company has taken over the landlord's management functions, including management of the common parts
- The managing agent only to the extent that the managing agent has been delegated specific control of the premises — but the legal responsibility remains with the RTM company regardless of delegation
The responsible person's obligations under the RRFSO are non-delegable. An RTM company that instructs its managing agent to "handle fire safety" remains the responsible person in law. If the managing agent fails to maintain an up-to-date fire risk assessment or fails to implement its recommendations, the RTM company — and potentially its individual directors — face criminal liability, not the managing agent. RTM directors must actively oversee fire safety compliance, not assume the managing agent has it covered.
The Fire Risk Assessment: What It Must Cover
The fire risk assessment is the core document of fire safety management. Under Article 9 of the RRFSO, the responsible person must carry out a suitable and sufficient assessment of the risks to which relevant persons are exposed in case of fire.
For a residential block, the assessment must cover:
- Ignition sources: potential sources of ignition in communal areas — electrical installations, communal heating and cooking equipment, items stored in communal areas
- Fuel sources: combustible materials in communal areas that could fuel a fire — flooring, wall coverings, stored items, refuse accumulations
- Oxygen sources: ventilation, open stairwells, and air movement patterns that affect fire spread
- Means of escape: the adequacy of escape routes, exit widths, travel distances, signage, emergency lighting, and evacuation strategy
- Fire detection and alarm: the coverage and adequacy of the communal fire detection and alarm system relative to the evacuation strategy
- Passive fire protection: the condition and adequacy of fire doors, fire-rated walls and ceilings, protected stairwells, and compartmentation measures
- Active fire protection: fire-fighting equipment, dry risers, sprinkler systems, and smoke control systems where provided
- Hazard-specific considerations: any specific features of the building that affect fire risk — cladding system, basement car parks, commercial ground floor uses, unusual occupancy
The assessment must produce a written action plan listing the measures required to reduce identified risks to an acceptable level, with priorities and timescales. This action plan must then be tracked to completion.
Fire Safety Obligations by Building Height
Fire safety obligations in residential blocks are tiered by height. All residential blocks must comply with the RRFSO. Additional obligations apply as building height increases.
All residential blocks
RRFSO 2005 — universal obligations- Suitable and sufficient fire risk assessment of common parts
- Annual review of the fire risk assessment
- Annual inspection of all fire doors in common parts
- Maintain all fire safety measures identified in the assessment
- Maintain fire detection and alarm system to BS 5839
- Maintain emergency lighting to BS 5266
- Provide fire safety information to residents
- Keep fire safety records for inspection
Blocks above 11 metres
Additional obligations from 2023- All obligations for all blocks, plus:
- Quarterly inspection of communal fire doors
- Annual inspection of flat entrance fire doors
- Carry out building assessment against safety standards
- Enhanced fire risk assessment covering external walls
- Notification obligations to Fire and Rescue Authority
- Provide information to leaseholders and residents on fire safety
Blocks above 18 metres
Higher-risk buildings — BSA 2022 regime- All obligations for 11m+ blocks, plus:
- Register with the Building Safety Regulator
- Quarterly inspection of ALL fire doors including flat entrances
- Safety case report demonstrating risk management
- Building safety manager (where multiple accountable persons)
- Residents' engagement strategy
- Mandatory occurrence reporting to Regulator
- More frequent regulatory inspections
Fire Door Inspections: The Current Requirements
The fire door inspection requirements introduced from 2023 onwards significantly increased the frequency of inspection obligations, particularly for taller buildings where fire compartmentation is more critical to the evacuation strategy.
| Door type and location | Building height | Inspection frequency |
|---|---|---|
| All communal fire doors (corridors, lobbies, stairwells) | All residential blocks | Annual |
| Communal fire doors | Above 11 metres | Quarterly |
| Flat entrance fire doors (where fire-rated) | Above 11 metres | Annual |
| Communal fire doors | Above 18 metres | Quarterly |
| Flat entrance fire doors | Above 18 metres | Quarterly |
What fire door inspections must check:
- The door leaf — no damage, warping, holes, or missing panels that compromise fire resistance
- The door frame — secure, no gaps between frame and wall that would allow fire or smoke passage
- Intumescent strips and smoke seals — present, intact, undamaged, correctly fitted in the rebate
- Self-closing mechanism — functioning correctly, closing the door fully without manual assistance, not held open or wedged
- Door furniture — handles, hinges, and locks in good condition and not compromising door closure
- Gap at the bottom of the door — should not exceed the specified gap for the door's fire rating
- Signage — correct fire door signage present and legible
- Glass panels — where present, correctly fire-rated and undamaged
One of the most common fire safety failures in residential blocks is fire doors wedged or propped open with door stops, chairs, or other objects. A fire door held permanently open provides zero fire or smoke containment — it is a through-route for fire spread that defeats the entire compartmentation strategy. Where fire doors in communal areas are found to be held open during a fire risk assessment or inspection, this must be treated as an immediate action item. Self-closing mechanisms that are inadequate (too weak, broken, or missing) must be replaced. Residents who hold fire doors open must be informed of the risk and the legal position in writing.
The Building Safety Act 2022: What Changes for Higher-Risk Buildings
The Building Safety Act 2022 created a new regulatory regime for residential buildings above 18 metres — "higher-risk buildings" — with significantly enhanced obligations that run in parallel with the RRFSO.
The key BSA 2022 concepts for RTM directors managing higher-risk buildings:
- Accountable person: the person who owns or has a legal obligation to repair the common parts of a higher-risk building. Where the RTM company has taken over management obligations including repairing obligations for the common parts, it may be an accountable person. Where there are multiple accountable persons (freeholder and RTM company), the Act requires them to cooperate and designates a principal accountable person.
- Principal accountable person (PAP): where there are multiple accountable persons, the PAP is the one who owns the structure and exterior of the building. The PAP has enhanced obligations including preparing the safety case report, applying to register the building, and managing the interface between accountable persons.
- Safety case report: a document demonstrating that the safety risks of the higher-risk building are being managed adequately. This is a dynamic document that must be kept current and submitted to the Building Safety Regulator as part of the registration and ongoing compliance process.
- Building Safety Regulator: the Health and Safety Executive-based regulator responsible for overseeing higher-risk buildings. All higher-risk buildings must be registered with the Regulator. The Regulator has inspection powers and enforcement authority independent of the Fire and Rescue Authority.
Residential blocks above 18 metres must be registered with the Building Safety Regulator. Operating — or allowing to be occupied — an unregistered higher-risk building is a criminal offence under the BSA 2022. Where an RTM company manages a building above 18 metres and registration has not been completed, this should be treated as an immediate compliance priority, not a deferred administrative task. Legal advice on the specific obligations and the registration process should be sought without delay.
Fire Safety Documentation: What the Responsible Person Must Keep
The written fire risk assessment and its action plan, dated, signed by the assessor, and evidencing the assessor's competence. Must be readily available for inspection by the Fire and Rescue Authority. For higher-risk buildings, must be reviewed more frequently and incorporated into the safety case report.
Written evidence that each recommendation in the fire risk assessment action plan has been completed — when it was completed, by whom, and what was done. Recommendations not yet completed should show progress status and revised completion dates. This is the record that demonstrates the responsible person is not just identifying risks but acting on them.
Written records of every fire door inspection, including the date, the inspector's details, the doors inspected, the condition found for each door, any defects identified, and the remedial action taken. Where defects are identified, the record should show when they were repaired and who carried out the repair. These records are critical evidence in any Fire and Rescue Authority inspection or prosecution.
Records of weekly partial tests of the fire alarm system, six-monthly full inspections and tests (BS 5839), and annual emergency lighting tests (BS 5266). Test records should specify the date, the person carrying out the test, the areas tested, any faults found, and their resolution. For higher-risk buildings, these records form part of the safety case evidence.
Evidence of fire safety information provided to residents — the building's evacuation strategy, fire action notices, information about fire doors and why they must not be held open, and any building-specific fire safety requirements. The responsible person must ensure residents have this information — not just that it has been produced. For higher-risk buildings, the resident engagement strategy must be documented.
For higher-risk buildings: the Building Safety Regulator registration certificate, the safety case report, records of mandatory occurrence reporting, the residents' engagement strategy, and correspondence with the Building Safety Regulator. These documents must be held securely and must be capable of being produced to the Regulator at any time.
Common Fire Safety Compliance Failures in Residential Blocks
No current fire risk assessment
The most fundamental failure — and the most common finding in Fire and Rescue Authority inspections. Operating without a current assessment is a criminal offence. Where the existing assessment is more than twelve months old and no review has been carried out, it is unlikely to meet the "suitable and sufficient" standard for a building where anything may have changed.
Assessor not competent
Fire risk assessments carried out by managing agents without fire risk assessment qualifications, or by contractors using generic templates, may not meet the legal standard. Assessors should hold recognised qualifications and be registered on a competency scheme (BAFE SP205, Institute of Fire Safety Managers, or equivalent).
Action plan recommendations not implemented
An assessment that identifies significant risks — fire doors without intumescent strips, blocked escape routes, inadequate emergency lighting — and whose recommendations sit unimplemented for months or years is worse than no assessment. The responsible person has identified the hazard and documented their failure to address it.
Fire doors in poor condition
Missing intumescent strips, failed self-closers, door leaf damage, and doors wedged open are the most common physical fire safety failures in residential blocks. Quarterly inspection in 11m+ buildings should identify these defects promptly — but only if the inspection is genuinely thorough, not a superficial walkthrough.
Combustibles stored in communal areas
Bicycles, mobility scooters, furniture, and packing materials in communal corridors and stairwells are among the most significant fire risk factors in residential blocks. Escape routes must be kept clear and free from combustible materials. The fire risk assessment should specifically address this and managing agents should enforce the restriction actively.
Higher-risk building not registered with BSR
Residential blocks above 18 metres that have not been registered with the Building Safety Regulator are in criminal breach of the BSA 2022. For RTM companies that took over management of an 18m+ building from a freeholder who had not completed registration, the RTM company should seek legal advice on its registration obligations without delay.
For the Building Safety Act's specific implications for block management — including accountable person obligations and the safety case — see Building Safety Act 2022: Compliance for Blocks Above 11m and 18m. For how waking watch transitions to ICAS interact with the fire strategy for higher-risk buildings, see How a Block in E3 Ended Waking Watch. For the planned maintenance schedule that keeps fire safety installations current, see Planned Preventative Maintenance: Why Your Block Needs a 5-Year Schedule.
Frequently Asked Questions
Under the RRFSO 2005, the responsible person for the common parts is the person with control of those parts. In an RTM-managed block, that is the RTM company. The obligation is non-delegable — appointing a managing agent or fire risk assessor does not transfer the legal responsibility. RTM directors can delegate tasks but cannot delegate liability. They must actively oversee fire safety compliance, not assume the managing agent has it covered.
Whenever there is reason to believe it is no longer valid, or after a significant change in the building, its use, or its occupancy. Annual review as a minimum is appropriate for all residential blocks. For buildings above 11 metres, more frequent review is expected given the higher consequences of any inadequacy. Where the existing assessment is materially out of date — or where material changes have occurred since it was last reviewed — commissioning a new assessment by a competent qualified assessor is the safest approach.
Annual inspection of communal fire doors for all residential blocks. For blocks above 11 metres: quarterly inspection of communal fire doors and annual inspection of flat entrance fire doors. For blocks above 18 metres: quarterly inspection of all fire doors including flat entrance doors. Inspections must check the door leaf, frame, intumescent strips, smoke seals, self-closing mechanisms, and hardware. Failed doors must be repaired or replaced promptly — a fire door with failed components is not a fire door.
Operating without a current fire risk assessment is a criminal offence under Article 32 of the RRFSO 2005. The Fire and Rescue Authority can serve enforcement notices, prohibition notices, or prosecute the responsible person. Prosecution can result in an unlimited fine or up to two years' imprisonment. Where a fire occurs and the assessment was absent or inadequate, the responsible person faces both criminal prosecution and civil liability. The fire risk assessment is a mandatory legal requirement, not optional documentation.
Blocks above 18 metres are higher-risk buildings under the BSA 2022 and must: be registered with the Building Safety Regulator; have a safety case report demonstrating risk management; appoint a building safety manager where there are multiple accountable persons; implement a resident engagement strategy; comply with mandatory occurrence reporting obligations; and submit to more frequent regulatory inspections by both the Building Safety Regulator and the Fire and Rescue Authority. These BSA 2022 obligations run in parallel with the RRFSO — both regimes apply. Occupying an unregistered higher-risk building is a criminal offence.
Is your block's fire safety compliance being actively managed?
Neon manages fire safety compliance as a core obligation for every block we manage — commissioning assessments by qualified assessors, tracking action plans to completion, scheduling fire door inspections at the required frequency, and maintaining the full documentation file. If your current agent cannot tell you when your last fire risk assessment was reviewed or when your fire doors were last inspected, talk to us.
Talk to Neon about your block →